Verify The Operation Of A Replacement Power/Cooling Module; Return A Faulted Part - Dell EMC PowerStore 1000 Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 1000:
Table of Contents

Advertisement

Figure 132. Plug in the power cord
3. For a DC power/cooling module, push the power cord plug into the connector until it snaps in place.

Verify the operation of a replacement power/cooling module

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the faulted power/cooling module.
3. On the Components card, under Rear View, expand ExpansionEnclosure.
4. Select the relevant PSU.
The status of the replacement power/cooling module should read Healthy. If the status is still Faulted, wait a few
minutes and refresh PowerStore Manager. If the status does not change, ensure that the power/cooling module is correctly
seated, or contact your service provider.

Return a faulted part

About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1. Package the faulted part in the shipping box that contained the replacement part.
2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3. For more information about returning customer-replaceable parts:
a. Open PowerStore Manager.
b. Click Settings on the upper right of the screen.
c. Click General Support.
d. Under Drives, Power Supplies, and Other Parts, click Return Part.
e. If your screen does not show the Return Part link, contact your service provider for instructions.
106
Expansion enclosure service procedures

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents