Table 2. Embedded module LEDs (continued)
LED
Port link
Node fault
Node power
Unsafe to remove

Power down the node

Power down the node as described in

Remove a faulted embedded module

Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts
the system cache.
2. Push the orange tab on the embedded module to release the lever.
Location
Power control
procedures.
State
Description
Off
No link established.
Green
Link up with high speed.
Amber
Link up with degraded speed.
Off
Link down.
Amber
Fault has occurred in the node or one of
its components.
Off
No fault has occurred. Normal operation.
Green
Node is on (main power).
Off
Node is off.
White
Do not remove the node. Improper
removal could cause data loss.
Off
Safe to remove the node when the node
has been properly prepared.
Base enclosure service procedures
37