Power Off A Powerstore X Model Appliance - Dell EMC PowerStore 1000 Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 1000:
Table of Contents

Advertisement

Steps
1. Log in to PowerStore Manager.
2. Under Hardware, select the appliance that you want to power off.
3. Under More Actions, select Power Down.
The Validation window opens.
4. Review any errors, warnings, and recommendations. Once the appliance passes all of the validation checks, click Next.
The Active Objects window opens.
5. Review the list of objects on the appliance that had I/O activity during the last five minutes.
6. Click Next.
The Confirm window opens.
7. Enter the service password, and click Power Down.
8. Check the status of the LEDs in the rear of chassis to verify that the appliance has powered off. Other than the LEDs for
the power supply unit, management port, and service port, all other LEDs on the appliance must be OFF.
9. Wait five minutes, and then disconnect the power cables from the base enclosure.
10. Disconnect the power cables from any associated expansion enclosures.

Power off a PowerStore X model appliance

Prerequisites
● Do not power off the appliance if you are replacing a hardware component. Identify the node that includes the faulted
hardware component, and power off only that node. For more information, see
page 113.
● Powering off an appliance results in the mapped hosts losing access to the data on the appliance. Before you begin, ensure
that you temporarily disconnect host access from all storage resources.
● Obtain the following information:
○ Address of the VMware vCenter server associated with the appliance
○ Associated vCenter server account credentials
○ Service tags of the appliance and, if applicable, the associated expansion enclosures
About this task
Use the following procedure to power off a single PowerStore X model appliance.
To power off all of the appliances in a cluster, see
Steps
1. Log in to PowerStore Manager.
2. Use PowerStore Manager to identify VMs that utilize the iSCSI or FC store of the appliance.
a. Select Storage > Storage Containers.
b. Select the first Storage Container.
c. Select Virtual Volumes.
d. Select the Show Filters icon.
e. Select Add Filter > Appliance.
f. Identify the VMs that are using storage on the appliance and the VMs that are running on the appliance.
g. Repeat these steps for each Storage Container.
3. In vCenter, power off the VMs identified in the previous step as well as any VMs using VMFS or volume on the appliance.
NOTE:
If you migrate compute VM storage objects to another appliance, you can migrate the compute VM to that
appliance instead of powering it off.
4. Launch an SSH client, and connect to the appliance using the management IP address.
5. Enter the username and password that is associated with the service account, and log in.
6. Run the following command to determine if the appliance you are shutting down is the primary appliance:
svc_cluster_management GetClusterStatus
118
Power control procedures
Power off a PowerStore X model
Power off a PowerStore X model node
cluster.
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents