Dell EMC PowerStore 1000 Installation And Service Manual page 43

Hide thumbs Also See for EMC PowerStore 1000:
Table of Contents

Advertisement

Figure 39. Embedded module LEDs
Table 3. Embedded module LEDs
LED
Embedded module power
Ethernet port link
Ethernet port activity
SAS port and activity link
Port link
Node fault
Node power
Unsafe to remove
Location
State
Amber
Off
Green
Off
Amber blinking
Off
Blue
Off
Green
Amber
Off
Amber
Amber or blue
blinking
Blue and amber
alternating (green
for 3 seconds)
Blue and amber
alternating at one
second intervals
Off
Green
Green blinking
Off
White
Off
Description
Embedded module has faulted.
No fault has occurred, normal operation.
Link established.
No link established.
Port activity.
No port activity.
SAS port link is up.
No link established.
Link up with high speed.
Link up with degraded speed.
Link down.
Fault has occurred.
System is booting.
System not initialized. A management IP
address has not been assigned.
Node in Service Mode.
No fault has occurred, normal operation.
Node is on (main power).
Node is initializing a serial over LAN
session (Standby Mode).
Node is off.
Do not remove the node. Improper
removal could cause data loss.
Safe to remove the embedded module
when the embedded module has been
properly prepared.
Base enclosure service procedures
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents