Identify A Faulted I/O Module From Powerstore Manager; Base Enclosure I/O Module Leds; Power Down The Node; Remove A Faulted I/O Module - Dell EMC PowerStore 1000 Installation And Service Manual

Hide thumbs Also See for EMC PowerStore 1000:
Table of Contents

Advertisement

Identify a faulted I/O module from PowerStore Manager

Before you replace an I/O module, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted I/O module.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that includes the I/O module that you need to replace.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Expand the node that includes the I/O module, and then select the relevant IoModule.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.

Base enclosure I/O module LEDs

Use the fault LEDs to identify the faulted part.
NOTE:
The ports look different depending on whether they are for copper or optical connections. The image below shows
ports for copper cables.
Figure 50. Base enclosure I/O module LEDs
Table 4. Base enclosure I/O module LEDs
LED
Port link
Power fault

Power down the node

Power down the node as described in

Remove a faulted I/O module

Steps
1. Pull the trigger mechanism on the I/O module handle to release it.
Location
Power control
procedures.
State
Description
Green or blue
Link up
Off
Link down
Green
Power on
Amber
Power fault
Base enclosure service procedures