VERSION 09/2016
OPERATING MANUAL
Surface spraying, electrostatics
Do not spray device parts using electrostatic equipment.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
Use only a damp cloth to clean the device.
Operation without Fluid
Avoid running the pump so that it sucks in air (without fl uid inside). The air, combined with
the vapor of fl ammable fl uids, can generate internal areas with an explosion hazard.
Periodically check that the pump is working, paying special attention to the presence of air
in the pumped fl uid, which may be caused by damaged diaphragms.
Avoid operating the pump with damaged diaphragms.
3.2

TYPE PLATE

Example
max. Air Pressure
1
max. Fluid Pressure
2
Tamb
3
Article No.
4
5
Year of manufacture - Serial No.
6
Check user manual before use!
Designed by Wagner International AG CH-9450 Altstätten, assembled in China
B_05368
ORDER NUMBER DOC 2366672
II 2G c IIB T4
1 Max. air pressure
2 Max. product pressure
3 Permissible ambient
temperature
4 Article number
5 Year of manufacture
6 Read the operating manual
before use