Type Plate - WAGNER TOPFINISH DD10 Operating Manual

Pneumatic double diaphragm pump
Hide thumbs Also See for TOPFINISH DD10:
Table of Contents

Advertisement

VERSION 12/2017
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames
or sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
Use only a damp cloth to clean the device.
Air in the pump fluid
Flammable gas mixtures can form if air reaches the pump fluid.
Prevent the pump from taking in air and running dry.
If air has been taken in, fix the leak. Then, fill slowly and in a controlled manner until
the air has escaped.
Air in the pumped fluid can be caused by damaged diaphragms.
Avoid operating the pump with damaged diaphragms.
Periodically check that the pump is working smoothly, paying special attention to
the presence of air in the pumped fluid.
Filling and emptying
Flammable gas mixtures can form in the fluid section or product hoses if the pump must
be emptied for maintenance.
Empty and fill the device slowly and in a controlled manner.
Avoid potentially explosive atmosphere in the surroundings.
3.3

TYPE PLATE

1
Wagner International AG, CH-9450 Altstätten
max. Air Pressure
2
max. Fluid Pressure
3
Tamb °C/°F
4
Article No.
5
Year of manufacture - Serial No.
6
Check user manual before use!
7
8
Designed and assembled by WAGNER in Switzerland.
B_06916
Designation
1 Manufacturer and CE Identification
2 Max. air pressure
3 Max. product pressure
4 Permissible ambient temperature
5 Article number
6 Model year - serial number
7 Read the operating manual before use
8 Indication of origin
ORDER NUMBER DOC 2366672
II 2G Ex h IIB T4 Gb X
0.8MPa; 116 psi
0.8MPa; 116 psi
4-40/39-104
TOPFINISCH DD10
9

Advertisement

Table of Contents
loading

Table of Contents