Repair Work; Repair Staff; Safety Instructions - WAGNER TOPFINISH DD10 Translation Of The Original Operating Manual

Pneumatic double diaphragm pump
Hide thumbs Also See for TOPFINISH DD10:
Table of Contents

Advertisement

VERSION 09/2016
OPERATING MANUAL
Problem
Pump runs fast when the
spray gun is closed.
Loss of power due to severe
icing.
If none of the causes of malfunction mentioned are present, the defect can be remedied by a WAGNER Service
Center.
10

REPAIR WORK

10.1

REPAIR STAFF

Repair work should be undertaken carefully by qualifi ed and trained personnel. They
should be informed of specifi c hazards during their training.
The following hazards may arise during repair work:
- Health hazard from inhaling solvent vapors
- Use of unsuitable tools and aids
A skilled person must check to ensure that the device is in a reliable state after it is repaired.
Carry out function test in accordance with Chapter 11.
10.2

SAFETY INSTRUCTIONS

Observe the safety instructions in Chapter 4 and Chapter 8.1.2.
Before a Repair
- Flush and clean the system.
After a Repair
- Carry out a safety checks in accordance with Chapter 8.2.3.
- Put the system into operation and check for leaks as described in Chapter 6.7.
- Function test in accordance with Chapter 11.
According DGUV regulation 100-500:
- The liquid ejection devices should be checked by an expert (e.g., WAGNER service
technician) for their safe working conditions as required and at least every
12 months.
- For shut down devices, the examination can be suspended until the next start-up.
ORDER NUMBER DOC 2366672
Cause
Valves worn.
There is a lot of condensation
water in the air supply.
Chapter 8.1.3.
Remedy
Replace the parts.
Install a water separator.