Identification; Explosion Protection Identification - WAGNER TOPFINISH DD10 Translation Of The Original Operating Manual

Pneumatic double diaphragm pump
Hide thumbs Also See for TOPFINISH DD10:
Table of Contents

Advertisement

VERSION 09/2016
OPERATING MANUAL
3

IDENTIFICATION

3.1

EXPLOSION PROTECTION IDENTIFICATION

As defi ned in the Directive 2014/34/EU (ATEX), the device is suitable for use in
potentially explosive areas.
CE mark (European Communities)
Symbol for explosion protection
Device class II
Category 2 (Zone 1)
Ex-atmosphere gas
C
Constructional security
Explosion group
Temperature class: maximum surface temperature < 135 °C; 275 °F
Maximum surface temperature
The maximum surface temperature of the pump depends on the operating conditions
(heated product) and not on the device (frictional heat).
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Ambient temperature
The permissible ambient temperature is: +10 °C to +60 °C; +50 °F to 140 °F.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g., air.
Safe handling of WAGNER spray devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device against steel or rusty iron.
Do not drop the device.
Use only tools that are made of a permitted material.
ORDER NUMBER DOC 2366672
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

8286

Table of Contents