WAGNER TOPFINISH DD10 Translation Of The Original Operating Manual page 28

Pneumatic double diaphragm pump
Hide thumbs Also See for TOPFINISH DD10:
Table of Contents

Advertisement

VERSION 09/2016
OPERATING MANUAL
6.8.3
BASIC CLEANING
Procedure
1. Visual check: personal safety equipment, grounding and all devices ready to use.
2. Place an empty, grounded collection tank (7) under the return tube (6).
3. Place the suction hose (3) in the grounded tank with fl ushing agent (4).
4. Adjust the pressure regulator (1) to approx. 0.2 MPa; 2 bar; 29 psi.
Flush via the return fl ow valve
5. Open return valve (5).
6. Slowly open the ball valve (8).
7. Adjust the air pressure on the pressure regulator (1) so that the pump runs
smoothly.
8. Flush the system until clean fl ushing agent fl ows into the tank (7).
9. Close ball valve (8).
10. As soon as there is no pressure remaining in the system, close the return valve (5).
Flush using gun
11. Point the spray gun, without nozzle, into the tank (7) and open it.
12. Slowly open the ball valve (8).
13. Rinse until clean fl ushing agent fl ows from the gun.
14. Close ball valve (8).
15. As soon as there is no pressure in the system, close the gun.
16. Secure the gun.
17. Dispose of the contents of the tank (7) according to the local regulations.
1 2
8
3
4
B_05380
ORDER NUMBER DOC 2366672
5
6
7
28

Advertisement

Table of Contents
loading

This manual is also suitable for:

8286

Table of Contents