INSTALLATION INSTRUCTIONS
BIN FASTENER (2)
RECEIVING
BIN
[3] Install:
• DEFLECTOR in the RECEIVING BIN
• RECEIVING BIN
• 2 BIN FASTENERS
Adjusting the FEED SHELF
1.5 mm
(0.06 in.)
film entry path
FILM
GUIDE
FEED
SHELF
H172_1017ACA
H172_1017AC
Setting the Frequency and Cycle Type
The PROCESSOR can be set to operate at different cycle speeds and frequencies:
• 60 Hz frequency, STANDARD cycle
• 50 Hz frequency, STANDARD cycle
• 60 Hz frequency, RAPID cycle
• 50 Hz frequency, RAPID cycle
The STANDARD cycle has a transport speed of 76.2 2.0 cm per minute (30 0.6 in. per minute).
The RAPID cycle has a transport speed of 101.6 1.5 cm per minute (40.1 0.8 in. per minute).
8
TOP COVER
DEFLECTOR
NIP
DETECTOR
CROSSOVER
ROLLERS
SCREW (4)
[1] Loosen the 4 SCREWS.
[2] Adjust the height of the FEED SHELF to 1.5 mm
⁄
1
(
in.) below the NIP of the DETECTOR
16
CROSSOVER ROLLERS.
[3] Insert a 35 x 43 cm sheet of film into the NIP of the
DETECTOR CROSSOVER ROLLERS.
[4] To adjust for squareness, use the film to align the
FILM GUIDE with the DETECTOR CROSSOVER
ROLLERS.
[5] Tighten the 4 SCREWS.
H172_1014BCA
H172_1014BC
04DEC98 – 7C8771