Checking the Replenishment Rates

DEVELOPER TUBING
METAL LATCH
H172_1005ACA
H172_1005AC
[5] Pull the DEVELOPER TUBING slightly and rotate it over the edge of the FRAME and into a GRADUATED
CYLINDER.
[6] Lift the UPPER ROLLER of the DETECTOR CROSSOVER AY for the correct time:
[7] When the REPLENISHMENT PUMP stops, check that the amount of solution in the GRADUATED CYLINDER
is correct for the film size and use condition. See the table on Page 31.
[8] If the replenishment rate is not correct, do the procedure "Adjusting the REPLENISHMENT PUMP" on Page 31.
[9] Connect the DEVELOPER TUBING by pushing it into the METAL LATCH until the DEVELOPER TUBING snaps
in place.
[10] Check the replenishment flow rate of the fixer solution by doing Steps
[11] Install the TOP COVER.
30
QUICK
DISCONNECT
Wear protective eyewear. The replenishment solutions
are pumped quickly and might splash.
GRADUATED
CYLINDER
FIXER TUBING
The DEVELOPER TUBING might be identified with a
red WIRE TIE.
Cycle
STANDARD
34 seconds
RAPID
25 seconds
* For 35 x 43 cm (14 x 17 in.) film
UPPER ROLLER
DETECTOR CROSSOVER
ASSEMBLY
2 DETECTOR
SWITCHES
Warning
[1] Remove the TOP COVER.
[2] Lift the UPPER ROLLER of the DETECTOR
CROSSOVER AY.
[3] Check that the replenishment solutions flow freely
through the TUBING located along the DRIVE
SIDE RACKS.
[4] Disconnect the DEVELOPER TUBING by
pressing the METAL LATCH.
Note
Time*
4
-
9
with the FIXER TUBING.
H172_1006BCA
H172_1006BC
04DEC98 – 7C8771