Section 5: Checking the System

Checking for Leakage

H148_0161CCA
H148_0161CA
5B6339 – January 1996
To allow correct operation of the LEVEL PROBES,
check that the level of the solutions is equal at both the
drive and nondrive sides of the DEVELOPER and
FIXER TANKS. The solution must cover the LEVEL
PROBES, located on the nondrive side, at the top edge
of the TANK ASSEMBLY. When the LEVEL PROBES
are not covered with solution, error codes E032
"Developer tank fill error" and E033 "Fixer tank fill error"
can occur and replenishment solutions are wasted.
[1] Fill the DEVELOPER, FIXER, and WASH TANKS
[2] Use a magnet to deactuate the COVER
[3] To provide for conduction of the LEVEL PROBES:
COVER
[4] Move AUXILIARY CIRCUIT BREAKERS CB2,
INTERLOCK
SWITCH
[5] Move the MAIN CIRCUIT BREAKER CB1 to the
[6] Check the PROCESSOR for leakage in:
MAGNET
tape
[7] Check that the OVERFLOW HOSES are draining
[8] Check that the DEVELOPER REPLENISHMENT
[9] Check that the correct REPLENISHMENT PUMP
Caution
to the overflow level with water.
INTERLOCK SWITCHES on the edges of the
PROCESSOR.
(a) Add 90 mL (3 fluidounces) of developer to
the DEVELOPER TANK.
(b) Add 90 mL (3 fluidounces) of fixer to the
FIXER TANK.
CB3, and CB4 to the "ON" position.
"ON" position.
(a) RECIRCULATION PUMP FITTINGS
(b) REPLENISHMENT PUMP FITTINGS
(c) TANK FITTINGS
(d) THERMOWELL ASSEMBLIES
(e) external plumbing
(f) DRAIN VALVES
water from the TANKS.
TUBE and the FIXER REPLENISHMENT TUBE
are connected to the correct plumbing FITTINGS.
is operating.