Connecting The Wires To Terminal Strip Tb1 - Kodak X-Omat 5000 RA PROCESSOR Installation Instructions Manual

Hide thumbs Also See for X-Omat 5000 RA PROCESSOR:
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

Connecting the Wires to TERMINAL STRIP TB1

Supply Voltage Connection Tables
POWER SYSTEM
5 Wire
L1,L2,L3,N
& Earth Ground
L1
L2
1
2
TB1
PROCESSOR
3 Wire
L1,L2, or N
& Earth Ground
1
2
TB1
PROCESSOR
H148_9000EC
22
NOMINAL SUPPLY
N
L3
4
3
L1
L2
OR
N
3
4
FREQUENCY
VOLTAGE
120/208
127/220
220/380
230/400
240/415
200
50/60
50/60
220
230
50/60
50/60
240
CONNECTION
(Hz)
DIAGRAM
60
SEE NOTE
50
B
SEE NOTE
50
K
SEE NOTE
50
L
SEE NOTE
50
M
SEE NOTE
C
SEE NOTE
D
SEE NOTE
E
SEE NOTE
F
SEE NOTE
January 1996 – 5B6339
A

Advertisement

Table of Contents
loading

Table of Contents