E.2

Pointek CLS300 Standard, cable version

When shortening a PFA cable, be sure to take extra care not to damage the PFA coating.
Methods
1. An angle grinder (preferably with a disc suitable for stainless steel)
Or
2. Wire cutters (suitable for piano cable Ø 6 to 9 mm).
Procedure
1. Loosen the three set screws and pull weight from the cable.
2. Grind/cut the cable to the required length, and then remove rough edges from the cable.
3. Ensure that cable strands are properly seated in the lay of the cable (i.e. no wire strands
sticking outside the normal cable profile). Make sure ALL strands are properly seated before
continuing the assembly.
4. Push the weight onto the cable while simultaneously rotating it counter-clockwise around
the cable. Make sure that no cable strands are pushed out of their position in the cable and
that the cable is fully inserted.
5. Re-fasten the weight by tightening the three set screws.
Pointek CLS200/CLS300 standard
Operating Instructions, 05/2021, A5E47827796-AA
CAUTION
Shortening the cable
E.2 Pointek CLS300 Standard, cable version