Technical data | Automax 100 | Basic module TS-AC B1-M2-1X

Technical data

Technical data - Automax 100 - Basic module TS-AC B1-M2-1X
Designation
Total weight
Dimensions
1)
Current consumption
Power consumption
2)
Min. operating temperature
Max. operating temperature
Place of installation
Ambient temperature
Max. relative air humidity
Max. installation height
Protection class
Supply voltage / external power
supply unit
A-weighted continuous sound level (at workplace of
operating personnel)
1)
Current consumption of the basic module without extension module and connected actuator.
2)
Power consumption of the basic module without extension module and connected actuator.
3)
Recommended by Bosch Rexroth for operation of the basic module up to its performance limits. Alternatively, a power
supply unit with lower output power can be used. ATTENTION! For this, the total power from basic module, extension
module and actuators to be connected must be determined.
4)
Micro-fuse 5 mm x 20 mm, 6.3 A, version mT (G fuse insert according to IEC 127-2-2).
Depth
Width
Height
Voltage (DC)
Current
Module fuse protection
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
Unit
Value
kg
3.5
mm
219,5
mm
364
mm
60,5
A
1.5
W
36
0
+40
---
Closed room
+0 to +40
%
90 at 20 ℃
m
3000 above sea level
IP20
V
24 (±10%)
I
6,5
3)
A
6.3
4)
dB
0
47/54