Voltage Supply For Extension Modules; Netgear Ethernet-Switch - Bosch Rexroth Automax 100 Series Operating Instructions Manual

Table of Contents

Advertisement

About this product | Automax 100 | Basic module TS-AC B1-M2-1X
For voltage supply, an external power supply unit with DC 24 V and 6.5 A (not included in
the scope of delivery) should generally be used.
ATTENTION! Depending on the application, it may be necessary to remove the connector
(). Observe the specifications of the modules to be combined with this basic module.
Safety socket (GND)
Safety socket (+24V/U
Safety socket (-1XG4)
Safety socket (+24V/U
Voltage supply of basic module
5.2.2

Voltage supply for extension modules

For attachment of extension modules, 2 slots are available. Each slot is assigned 3 safety
sockets for voltage supply of extension modules.
The following voltages are supplied:
 GND (blue safety socket)
 U
DC 24 V (red safety socket)
LS
 U
DC 24 V (green safety socket)
A
 Information on the attachment of extension modules can be found in chapter
and
modification" as of page [45].
Slot 1 for extension module
Voltage supply for extension module
(slot 1)
Slots for extension modules
Attached extension modules are secured via the two knurled screws of the respective slot.
5.2.3

NETGEAR Ethernet-switch

The following information on the Ethernet switch are an excerpt of the data sheet and the
installation manual of the NETGEAR Ethernet switch.
„Connector XVB-4/19" symbol
)
Symbol „Contact protected measuring
LS
line" symbol
)
A
Slot 2 for extension module
Voltage supply for extension module
(slot 1)
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
19/54
„Extension

Advertisement

Table of Contents
loading

This manual is also suitable for:

Basic module ts-ac b1-m2-1x