Diassembly and replacement | Automax 100 | Basic module TS-AC B1-M2-1X
Diassembly and replacement
Compromising of the training system, individual components or other assets. Risk
for safe operation of the training system!
Risk of injury or death for operator or third
Chapter
„Safety
instructions" as of page [7] in these operating instructions must
always be observed!
The basic module TS-AC B1-M2-1X serves as the basic module of the modular Automax
100 device family. To disassemble the basic module TS-AC B1-M2-1X, only the electrical
connection to the external power supply must be disconnected. To do this, disconnect the
touch-proof test leads „1" and „2" at the rear of the device. The insulated connection plug „3"
does not have to be disconnected for disassembly. See also the following figure.
1
Contact-protected measuring line 4
mm, blue (mat.-no.: 1827003219)
2
Contact-protected measuring line 4
mm, red (mat.-no.: 1827003218)
Electrical isolation of the base module from an external power supply unit
If the basic module TS-AC B1-M2-1X has already been equipped with an extension module,
the extension module is removed in the reverse order as described in the chapters
„Extension by 1
level" as of page [45] and
WARNING
3
Insulated connector 4 mm, connector
width 19 mm (mat.-no.: R911405746)
„Extension by 2
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
39/54
level" as of page [46].