Incorrect handling during connection or disconnection can cause damage at the
safety socket or the safety plug. In case of damaged parts, functional safety of the
plug-in connection can be no longer ensured!
Risk of damage of the basic module TS-AC B1-M2-1X, property damage, malfunction!
 Before connection, make sure that
Plugs and socket are not broken, cracked or deformed
Contact pins are not bent, broken or corroded
 Make sure that plug and socket are not jammed and can be connected without force
Irregularities, variations, faults, defects during assembly or test!
Risk of damage of the basic module TS-AC B1-M2-1X, property damage!
 Do not put the basic module into operation or take it out of operation without undue
delay
 Determine the cause and remedy the defect. If this is not possible,
inform the Bosch Rexroth customer service
Preparations for set-up
Proper execution of assembly requires that:
 The delivery, the transport and the unpacking according to chapter
product" as of page [25] and chapter
been properly completed
 All parts required are within reach and functional
Consider the following aspects before the final set-up:
 Make sure sufficient space is available for the basic module TS-AC B1-M2-1X. Also refer
to chapter
„Operator
workstations" as of page [12]. Any possible attachment parts
should be taken into account
 Check the levelness of the assembly station
 Make sure that there is sufficient lighting at the set-up location
 Ensure compliance with the prescribed installation position of the basic module
7.4.1
Connecting the power supply – U
For electrical connection, an external power supply unit for DC 24 V is required. For
information on the power supply unit specifications, refer to chapter
as of page [28]. Additionally, the contact-protected measuring lines (red and blue) and the
insulated connector included in the scope of delivery of the basic module are required.
Information can be found in chapter
For connection of the basic module to the external power supply unit:
Connect port 0 V (GND) of the external power supply unit to the blue safety socket
(GND) of the basic module with the blue measuring line ()
Connect port +24 V (+) of the external power supply unit to the red safety socket (+24
V/U
) of the basic module with the red measuring line ()
LS
Connect the green safety socket (+24 V/U
of the basic module with the connector
NOTICE
NOTICE
„Unboxing the
product" as of page [27] have
internally supplied
A
„Scope of
delivery" as of page [17].
) to the lower black safety socket (-1XG4)
A
„Transporting the
„Required
accessories"