Operating | Automax 100 | Basic module TS-AC B1-M2-1X

Operating

Compromising of the training system, individual components or other assets. Risk
for safe operation of the training system!
Risk of injury or death for operator or third
 Chapter
„Safety
instructions" as of page [7] in these operating instructions must
always be observed!
In order to ensure safe operation of the basic module TS-AC B1-M2-1X, the following
conditions must be met:
 Assembly, establishing of the power supply and installation have been carried out
properly. Refer to chapter „Assembly" as of page [27]
 First commissioning was successfully completed. Refer to chapter
as of page [33]
For operation of the basic module, one or more extension modules are required. The basic
module offers 2 slots for insertion of extension modules and securing with knurled screws.
Additionally, voltage supply of these extension modules is established via the safety
sockets. Operation of the basic module depends on the attached extension module.
9.1

Configuration of the NETGEAR Ethernet-switch

For operation of the basic module with extension modules, the NETGEAR Ethernet switch
does not need to be configured. The default settings are sufficient. If it is still necessary to
access the configuration menu, enter the IP address into the address bar of the web
browser.
This is further explained in the following description.
For connection to the NETGEAR Ethernet switch, the IP address of the computer must be
adjusted. For this, administrator rights are required. A patch cable is required to establish
the connection, e.g. CAT.6A 2XRJ45-ST.
For connection, plug the patch cable into the Ethernet port of your PC and the other end into
the Ethernet port 1 of the NETGEAR Ethernet switch.
Network cable connection
The screenshots and settings have been made on a PC with Windows 10 operating system
and only apply for this configuration.
Activate the main switch (if applicable) of the external power supply unit
Activate the main switch at the front of the basic module
The green power LED of the Ethernet switch is flashing
Switch on the computer and start it up
Press „Win + r" to open the „Run" window
DANGER
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
33/54
„First
commissioning"