Install The Access Point Directly On A Wall; Install The Access Point On A Suspended Ceiling Or A Drop Ceiling With A Flat T-Bar; Install The Access Point On A Flat T-Bar Using Main Mounting Bracket - Extreme Networks ExtremeWireless AP410i Installation Manual

Table of Contents

Advertisement

Install the Access Point Directly on a Wall

Install the Access Point Directly on a Wall
About This Task
If you do not want to use the main mounting bracket that ships with the access point, you can install the
access point directly on a wall using two Phillips pan head screws.
Tip
The best practice is to use the main mounting bracket for wall installations.
Procedure
1. Measure and drill two holes 4.100 in. (104 mm) apart from each other on the wall.
2. Insert the Phillips pan head screws into the mounting holes on the wall.
Use screw-in anchors, if needed.
3. Connect the Ethernet cable RJ45 into the GE1 port.
4. Align the access point against the screw heads and slide it down.
5. Ensure that the access point is secured in place.
If the access point is loose, unmount it and decrease the distance between the two screw heads.
Then, remount the access point.
Install the Access Point on a Suspended Ceiling or a Drop Ceiling with a
Flat T-bar
About This Task
For suspended ceiling or drop ceiling installation, the main mounting bracket is used directly on the T-
bar. If there is a ceiling tile protrusion, the optional T-bar adapter is attached to the main mounting
bracket prior to T-bar installation.
The access point may be mounted to a suspended or a drop ceiling using:
#37201, stainless-steel main mounting bracket to a flat 15/16 in. wide T-bar, with flat ceiling tiles
#37201, stainless-steel main mounting bracket with KT-135628-01 adapter to a flat T-bar
#37211, WS-MBI-DCFLUSH bracket to a flat T-bar, with flat ceiling tiles
#30518, WS-MBI-DCMTR01 bracket to a T-bar

Install the Access Point on a Flat T-bar Using Main Mounting Bracket

Before You Begin
Ensure that the T-bar meets the following conditions before installing the main mounting bracket on a
flat T-bar:
T-bar width must be 15/16 in. (24 mm).
T-bar bottom must be flat, all the way across the ceiling.
20
ExtremeWireless™ Access Points AP410i/e
Note
th
Leave 1/8
in. gap between the screw head and the wall.
Install the Access Point