Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
• FQXPMSR0031L: Failed to remove existing virtual disk
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of RAID adapter and disk drives are both healty.
3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter.
4. Reboot the machine and retry to remove the existing virtual disk.
5. If the problem persists, please contact technical support.
Service Action:
1. Review PD Steps.
2. Enter RAID HII to check the controller status
3. Replace the hard drives
4. Replace the RAID adapter
5. If problem persists, escalate to next level of support
• FQXPMSR0032I: Removed existing virtual disk successfully.
Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
• FQXPMUP0001K: The system configuration does not meet the prerequisite
Severity: Warning
User Action:
1. Follow prompts to update the firmware and retry the update.
2. If the problem persists, please contact technical support.
.
Chapter 4
XClarity Provisioning Manager events
265