2. 2. If the problem still exist then replace the adapter.
3. 3. If the problem still exist then contact local service.
Service Action:
uefi_defined
• FQXSPIO0008N: A PCI SERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI SERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0234
User Action:
Complete the following steps to solve:
1. 1. Reseat the adapter or other slot.
2. 2. If the problem still exist then replace the adapter.
3. 3. If the problem still exist then contact local service.
Service Action:
uefi_defined
• FQXSPIO0010I: A Correctable Bus Error has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Correctable Error.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0238
User Action:
Information only; please correct the error recorded in system log to resolve the error
Service Action:
Information only; no action is required.
• FQXSPIO0011N: An Uncorrectable Error has occurred on [SensorElementName].
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
60
ThinkSystem SR850 V2 System Events Service Guide