Lenovo ThinkSystem SR850 V2 Service Manual page 168

Hide thumbs Also See for ThinkSystem SR850 V2:
Table of Contents

Advertisement

Service Action:
Information only; no action is required.
• FQXSPSR0001N: Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0524
User Action:
Using XCC web or LSA or Storcli to check the status of every virtual disk on your system, resolve the
problem on the problematic virtual disk(s).
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Check the status of every virtual disk on the system and resolve the problematic virtual disk(s).
3. Check Lenovo Support for known service bulletins and Tech tips.
4. If problem persists, escalate to next level of support.
• FQXSPSR2001I: Sensor [SensorElementName] has deasserted the transition to non-recoverable
from a less severe state.
This message is for the use case when an implementation has detected that the Sensor transition to non-
recoverable from less severe has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0525
User Action:
Information only; no action is required
Service Action:
Information only; no action is required.
• FQXSPSS4000I: Management Controller Test Alert Generated by [arg1].
This message is for the use case where a user has generated a Test Alert.
Severity: Info
Serviceable: No
Automatically notify Support: No