Lenovo ThinkSystem SR850 V2 Service Manual page 260

Hide thumbs Also See for ThinkSystem SR850 V2:
Table of Contents

Advertisement

User Action:
1. Restart BMC via supported method and reboot the system.
2. Reflash BMC firmware.
3. Reboot system and retry OS booting.
4. Perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
5. If the problem persists, please contact technical support.
Service Action:
1. Review PD Steps.
2. Download the update package for LXPM, UEFI, XCC and apply it using (onecli or XCC WEB).
3. Install OS using manual method.
4. If problem persists, escalate to next level of support
• FQXPMOS0002K: Failed to read Deployment Manager Signature from USB.
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. If the problem persists, reflash BMC firmware.
4. Retry OS deployment.
5. If the problem persists, perform AC reset or virtual reseat.
Note: When performing AC reset, after powering off AC, wait several seconds before powering on
AC. After AC power is restored, power on the host system.
6. If the problem persists, please contact technical support.
Service Action:
1. Review PD Steps.
2. Download the update package for LXPM, UEFI, XCC and apply it using (onecli or XCC WEB).
3. Install OS using manual method.
4. If problem persists, escalate to next level of support
• FQXPMOS0003K: Failed to copy Windows boot files to target
Severity: Warning
User Action:
1. Ensure proper operation of the virtual USB connection.
2. Restart BMC via supported method and reboot the system.
3. Reflash BMC firmware.
4. Retry OS deployment.
5. Perform AC reset or virtual reseat.