Lenovo ThinkSystem SR850 V2 Service Manual page 138

Hide thumbs Also See for ThinkSystem SR850 V2:
Table of Contents

Advertisement

Alert Category: Critical - Redundant Power Supply
SNMP Trap ID: 9
CIM Prefix: PLAT CIM ID: 0811
User Action:
Information only; no action is required.
Service Action:
Information only; no action is required.
• FQXSPPW4001I: PCIe Power Brake for [arg1] has been [arg2].
This message is for the use case where PCIe Power Brake.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0243
User Action:
Check if system have fan fail error, Raidlink CEM fail occurring or Ambient temperature over 35C,
implement the "error" service action to recovery the system and reduce ambient temperature under 35C.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Check Lenovo support site for an applicable service bulletin or firmware update for the system or adapter that
applies to this error.
3. If problem persists, escalate to next level of support.
• FQXSPSB2000I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
Service Action:
Information only; no action is required.
• FQXSPSD0000I: The [StorageVolumeElementName] has been added.