Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Replace the affected Power Supply by confirming PFA alert in the System Event Log (SEL) or the System
Management Module (SMM) Log.
3. If problem persists, escalate to next level of support.
• FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0098
User Action:
Information only; no action is required
Service Action:
Information only; no action is required.
• FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Make sure power cables are connected correctly.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Replace the affected Power Supply.
3. If problem persists, escalate to next level of support.
• FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
122
ThinkSystem SR850 V2 System Events Service Guide