• FQXSFIO0012M: A PCIe system error has occurred on Bus [arg1] Device [arg2] Function [arg3].
The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Check the log for a separate error related to an associatedPCIe device and resolve that error.
2. If the problem persists, move the affected adapter to a different slot. If a slot is not available or error recurs,
replace the affected adapter.
3. Inspect processor socket. If socket is damaged, replace the system board.
4. If problem persists, escalate to next level support.
• FQXSFIO0013I: The device found at Bus [arg1] Device [arg2] Function [arg3] could not be
configured due to resource constraints. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The physical slot number is [arg6].
Severity: Warning
User Action:
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded,
reseat adapter and any attached cables.
2. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.(NOTE: It may be necessary to disable unused option ROMs from UEFI F1
setup, OneCLI utility, or using adapter manufacturer utilities so that adapter firmware can be
updated.)
3. Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Perform PD on PCIe error.
3. If problem persists, replace system board.
4. If problem persists, escalate to next level support.