Configuring the settings can be done one of two ways:
– Press a number on the key pad that corresponds to the setting you want to configure.
– Use the arrow keys to highlight the setting you want to change, and then press the OK key.
Press the Cancel key to exit a menu.
NOTE:
You must specify the interface settings before specifying VoIP settings. For example, you must
configure the Network, LAN, and other applicable settings for a xDSL line.
2
Select General Setup, and then specify the settings.
The available settings depend on the call control selected. The following table describes the
settings.
Setting
CC Standard
Auto Answer
Alias (H.323 or SIP)
H.323 ID (H.323)
Bearer Capability
(H.323)
Calling Plan (H.323)
Calling Type (H.323)
Called Plan (H.323)
June 2014
Description
Specify the call control standard: H.323 (Fast connect), H.323 (Full), SIP,
SCCP, or MGCP.
NOTE: Some call controls are options, so if your unit is not equipped with
the option, you will not see all of the selections.
Specify whether to automatically answer incoming calls. Yes means all
incoming calls are answered automatically. No is the typical setup and
means that calls will be answered manually.
For H.323, this is the phone number alias that will be associated with the
phone that you are trying to emulate. This phone number will be included
in the connection request messages that are exchanged with the Gate-
keeper/Proxy or other endpoint devices.
For SIP, this specifies the registrar. If you have a network that uses one
server for registration (the registrar) and another for placing and receiving
calls "Alias" specifies the registrar. ("Proxy IP" on the Proxy Settings menu
specifies the server used for placing and receiving calls.) There are two
ways to get the Alias for SIP - you can specify the Alias by directly entering
a value by yourself; or alternatively, by querying a web server to get back
an Alias value. Using the latter way, you need to enter the URL of the web
server.
Enter the ID, using up to 40 characters.
This is an ID element field in the ALIAS information that is sent to the
Gatekeeper during all registration and request messages.
The H.323 gateway registers with an H.323 ID. This is either an email ID
or an E.164 address. For example:
Email ID (H.323 ID): gwy-01@domain.com
E.164 Address: 5125551212
This sets the Bearer Cap information element in the H.323 setup message
for outgoing calls: Voice, 3.1K audio, Unrestricted digital
If required, this sets the Calling Party Numbering Plan information element
in the H.323 setup message for outgoing calls: Unknown, ISDN/Tele-
phony, Data, Telex, National, Private.
If required, this sets the Calling Party Type information element in the
H.323 setup message for outgoing calls: Unknown, International, National,
Network Specific, Subscriber, Abbreviated.
If required, this sets the Called Party Numbering Plan information element
in the H.323 setup message for outgoing calls: Unknown, ISDN/Tele-
phony, Data, Telex, National, Private.
SmartClass TPS User's Guide