Table 10-13
Measurement settings (continued)
Data
Vacuum capacitance
Vacuum capacitance c
4
PDC settings
Output voltage (DC)
Record depolarization
data
Depolarization time
5
FDS settings
Output voltage (AC)
Noise suppression
Pre-measurement checks
Check for noise and
and
connectivity problems
problems
problems
Delay the start of the measurement until
ay the start of the measurement
tart of the measur
The depolarization current
The depolarization current
rization curren
falls below
falls below
s
The time elapsed
The time
The time elapsed
1. Applies to
1. Applies to cylindrical electrodes.
2. Applie
2. Applies to disk electrodes.
3. For
3. For the specified geometry of the electrodes, SPECTANO Analyzer Suite calculates the vacuum
capacitance automatically. If you select Others in the test cell settings, enter the vacuum
c
capacitance manually.
4. Only available for the PDC and combined measurement modes selected in the sweep settings
under Measurement type.
5. Only available for the FDS and combined measurement modes selected in the sweep settings
under Measurement type.
Description
Vacuum capacitance of the test cell
3
0
Peak output voltage for the PDC method
Select the Record depolarization data check
box to record and display the depolarization
current.
Time interval during which the test object
discharges
Peak output voltage for the FDS method
put voltage for the FDS method
ge for the FDS me
Select the Standard or Improved option for the
the Standard
andard or or Improved
suppression of the noise interference. If you
pression of the noise interferenc
on of the noise inter
select Improved, the noise-to-signal ratio and,
elect Improved
, the noise-to-sig
mpro
consequently, the measureme
consequently, the measurement accuracy will be
sequently, the mea
improved but the measurement time will increase.
improved but the measurem
mproved but the mea
Select the
Select the
Select the
Check for
Check for noise
Check for noise and connectivity problems
check box to check for noise and connectivity
check box to c
heck b
problems before starting a test
problems be
rob
4
Select this option and enter the threshold
Sele
depolarization current to delay the start of the
d
measurement until the depolarization current falls
below the threshold.
Select this option and enter the time limit to delay
the start of the measurement until the time limit
elapsed.
SPECTANO Analyzer Suite
method
data check
check
ation data
the depolarization
arization
which the test object
ich the test object
opti
prov
the
55