Possible Combinations Of Outdoor Unit And Domestic Hot Water Tank - Daikin Altherma 3 M Installer's Reference Manual

Hide thumbs Also See for Altherma 3 M:
Table of Contents

Advertisement

5.2.2 Possible combinations of outdoor unit and domestic hot water tank

EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Tank
Polypropylene tank:
EKHWP300PB
EKHWP500PB
For installation instructions, see the installation manual of the domestic hot water
tank and the addendum book for optional equipment.
Human Comfort Interface (BRC1HHDA) used as room thermostat
The Human Comfort Interface (HCI) used as room thermostat can only be used in
combination with the user interface connected to the outdoor unit.
The Human Comfort Interface (HCI) used as room thermostat needs to be
installed in the room that you want to control.
For installation instructions, see the installation and operation manual of the
Human Comfort Interface (HCI) as room thermostat, and the addendum book for
optional equipment.
Flow switch (EKFLSW1)
If you add glycol to the water, you also need to install a flow switch (and set
[E-0D]=1).
For installation instructions, see the installation manual of the flow switch.
Smart grid relay kit (EKRELSG)
The installation of the optional Smart grid relay kit is required in case of high
voltage Smart grid contacts (EKRELSG).
For installation instructions, see
Combination table
Outdoor unit
EKHWS*D*
EBLA09~16
EDLA09~16
(a)
When using a third-party tank, make sure it complies with the minimum requirements (see
"Third-party tank
requirements" [
Third-party tank requirements
In case of a third-party tank, the tank shall adhere to the following requirements:
The heat exchanger coil of the tank is ≥1.05 m² and ≤3.7 m².
The tank thermistor must be located above the heat exchanger coil.
The booster heater must be located above the heat exchanger coil.
NOTICE
Performance. Performance data for third-party tanks CANNOT be provided, and
performance CANNOT be guaranteed.
5
|
Tank with pressurised solar system.
For these tanks, the booster heater
option (EKBH3S) must be installed.
"To connect a Smart
Domestic hot water tank
EKHWSU*D*
O
O
O
O
4
 29]).
About the units and options
Remark
4
Grid" [
 118].
EKHWP*
Third-party
O
O
Installer reference guide
tank
(a)
O
(a)
O
29