Daikin Altherma 3 M Installer's Reference Manual page 203

Hide thumbs Also See for Altherma 3 M:
Table of Contents

Advertisement

EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
#
Code
[9.8.8]
N/A
Allowed heaters during preferential kWh rate power supply
[D‑00]
Booster heater
0
Forced OFF
1
Permitted
2
Forced OFF
3
Permitted
Smart Grid operation modes
The 2 incoming Smart Grid contacts (see
activate the following Smart Grid modes:
Smart Grid contact
1
0
0
1
1
Free running:
The Smart Grid function is NOT active.
Forced off:
The unit forces OFF the compressor and the heaters (backup heater, booster
heater).
The safety functions (water pipe freeze prevention, drain prevention, room frost
protection) and defrost are NOT overruled.
Recommended on:
Description
Limit setting kw
Restriction: Only applicable if:
[9.8.4]=Smart grid.
There is no pulse meter (power meter) for
photovoltaic
panels
Electricity meter 2 = None)
Normally, when a pulse meter is available, the
following happens:
The pulse meter measures the power
produced by the photovoltaic panels.
The unit limits its power consumption during
the Smart Grid's "Recommended ON" mode to
only use the power provided by the
photovoltaic panels.
However, when the pulse meter is not available,
you can still limit the unit's power consumption
using this setting (Limit setting kw). This
prevents overconsumption and thus requiring
the use of power from the grid.
Backup heater
Forced OFF
Permitted
"To connect a Smart
[9.8.5] Smart grid operation
2
0
Free running
1
Forced off
0
Recommended on
1
Forced on
11
Configuration
|
available
([9.A.2]
Compressor
Forced OFF
4
Grid"  [
  118]) can
mode
Installer reference guide
203