Symptom: You are feeling too cold (hot) in your living room..................57 Symptom: The water at the tap is too cold........................57 Symptom: Heat pump failure ............................58 User reference guide EBLA09~16DA + EDLA09~16DA Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 3
Overview: Relocation ..............................60 10 Disposal 11 Glossary 12 Installer settings: Tables to be filled in by installer 12.1 Configuration wizard............................... 63 12.2 Settings menu ................................. 64 EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Format: Paper (in the box of the outdoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations. EBLA09~16DA + EDLA09~16DA...
About this document Daikin Residential Controller app If set up by your installer, you can use the Daikin Residential Controller app to control and monitor the status of your system. For more information, see: http://www.onlinecontroller.daikineurope.com/ Breadcrumbs Breadcrumbs (example: [4.3]) help you to locate where you are in the menu structure of the user interface.
Page 6
Example: " 1–3 Figure title" means "Figure 3 in chapter 1". Indicates a table title or a reference to it. Example: " 1–3 Table title" means "Table 3 in chapter 1". EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Do NOT place any objects containing water on the unit. CAUTION ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the unit. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer. ▪ Be aware that the refrigerant inside the system is odourless. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 9
Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Underfloor heating c Heat pump convectors or fan coil units d User interface e Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) f Domestic hot water (DHW) tank EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Operation > Space heating/cooling), room frost protection operation –if enabled– can still activate. However, for leaving water temperature control and external room thermostat control, the protection is NOT guaranteed. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 12
You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 13
X2. X1, X2 Outdoor ambient temperature Y1~Y4 Desired leaving water temperature a WD curve before changes b WD curve after changes c Slope d Offset EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 14
For more information, see also: ▪ "5.4 Turning operation ON or OFF" [ 24] ▪ "5.6 Space heating/cooling control" [ 26] ▪ "5.8 Preset values and schedules" [ 34] ▪ "5.9 Weather-dependent curve" [ 44] EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
[5.3] and Reheat setpoint [5.4]. More information For more information, see also: ▪ "5.4 Turning operation ON or OFF" [ 24] ▪ "5.7 Domestic hot water control" [ 30] ▪ "5.8 Preset values and schedules" [ 34] EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Slot for WLAN cartridge With the WLAN cartridge, the installer can connect the system to the internet. As user you can then control the system via the Daikin Residential Controller app. Note: This slot cannot be used for SD cards.
Page 17
: Turn the right dial. Navigate through the possible values and settings. ▪ : Press the right dial. Confirm your choice and go to the next menu item. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
(**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
26 Feb 2020 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 20
Smart energy is currently being used for domestic hot water. Space operation mode Cooling Heating Outdoor / quiet mode Measured outdoor temperature Quiet mode active Outdoor unit Domestic hot water tank Standalone tank installed EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 21
"8.1 To display the help text in case of a malfunction" [ 56] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
User settings mode and quiet mode. Displays data and information about the Information outdoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Restriction: Only displayed if a wireless LAN Wireless gateway (WLAN) is installed. Contains settings needed when configuring the Daikin Residential Controller app. 5.3.3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value.
Space heating/cooling operation a Space heating/cooling operation ON b Space heating/cooling operation OFF EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Tank), disinfection mode will remain active. However, if you turn it OFF while disinfection is running, an AH error occurs. 1 Go to [C.3]: Operation > Tank. Operation Space heating/cooling Tank 2 Set operation to On or Off. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
About space operation modes Your unit can be a heating or a heating/cooling model: ▪ If your unit is a heating model, it can heat up a space. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 27
2 Select a month. 3 For each month, select an option: ▪ Reversible: Not restricted ▪ Heating only: Restricted ▪ Cooling only: Restricted 4 Confirm the changes. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature. 1 Go to [1]: Room. Room EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
4 hours starting from the scheduled start-up of disinfection. If the booster heater is restricted during disinfection, this function will NOT be successful and the applicable warning AH will be generated. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value. 60°C 50°C 40°C 15°C 00:00 07:00 14:00 21:00 DHW tank temperature t Time EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
(=reheat tank temperature – hysteresis value; example: 35°C), the DHW tank heats up until it reaches the reheat set point (example: 45°C). This ensures that a minimum amount of hot water is available at all times. Example: EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Activate or deactivate Powerful operation as follows: 1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Bivalent is enabled by the installer. Additional to the user-defined preset values, the system also contains some system-defined preset values that you can use when programming schedules. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
User defined 1 3 Select Select. Delete Rename Select 4 Select the schedule that you currently want to use. Possible schedules The table contains the following information: EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 36
Off: When the system is NOT allowed to heat additional zone in heating up the additional zone. mode. ▪ On: When the system is allowed to heat up the additional zone. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 37
Possible actions: You can use the following system-defined preset values: ▪ Quiet ▪ More quiet ▪ Most quiet "About quiet mode" [ 50]. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
5 Program the schedule for Saturday and copy it to Sunday. 6 Give the schedule a name. To go to the schedule 1 Go to [1.1]: Room > Schedule. 2 Set scheduling to Yes. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 39
2 Select Delete. Delete Edit Copy 3 Select OK to confirm. To program the schedule for Monday 1 Select Monday. User defined 1 2 Select Edit. Delete Edit Copy EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 40
1 Select Monday. User defined 1 2 Select Copy. Delete Edit Copy Result: Next to the copied day, "C" is displayed. 3 Select Tuesday. User defined 1 EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 41
8:00 21°C 23:00 18°C --:-- 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. 8 Select Paste. Result: User defined 1 EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Electricity: 12 euro cents/kWh [7.5.1]=12 To set the gas price 1 Go to [7.6]: User settings > Gas price. 2 Select the correct gas price. 3 Confirm the changes. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 43
To set the electricity price in case of an incentive per kWh renewable energy Calculate the value for the electricity price with following formula: ▪ Actual electricity price+Incentive/kWh EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
See "5.9.4 Using weather-dependent curves" [ 47]. 5.9.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Examples Weather-dependent curve when slope is selected: Weather-dependent curve when offset is selected: EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
5.9.4 Using weather-dependent curves Configure weather-dependent curves as following: To define the setpoint mode To use the weather-dependent curve, you need to define the correct setpoint mode: EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 48
You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank. When the maximum or minimum setpoint is reached, the curve flattens out. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
↓ ↑ ↓ ↓ ↓ ↓ ↓ "5.9.2 2-points curve" [ 45]. 5.10 Other functionalities 5.10.1 To configure time and date 1 Go to [7.2] User settings > Time/date. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Setting the starting date and ending date of your holiday. Activating the holiday mode. To check if holiday mode is activated and/or running is displayed on the home screen, holiday mode is active. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
About the WLAN cartridge The WLAN cartridge connects the system to the internet. As user you can then control the system via the Daikin Residential Controller app. This needs the following components: WLAN cartridge The WLAN cartridge needs to be inserted in the user interface.
Page 52
The Daikin Residential Controller app needs to be installed on the user's smartphone. See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface: [D] Wireless gateway...
Page 53
[D.6] Cloud connection: Read out the status of the connection to the cloud: 1 Go to [D.6]: Wireless gateway > Cloud connection. 2 Read out the connection status: ▪ Not connected ▪ Connected EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Program to turn ON the domestic hot water pump only during periods of the day when instant hot water is necessary. Example: In the morning and evening. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit. Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Conditions: The user permission level is set to advanced end user. 1 Go to [8.2]: Information > Malfunction history. You see a list of the most recent malfunctions. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
DHW tank to a preset value (Eco setpoint = lower tank temperature) during the day. "5.8.2 Using programming schedules" [ 35] and "5.8.3 Schedule screen: Example" [ 38]. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
To be performed by the installer: Perform hydraulic balancing to assure that the flow is correctly distributed between the emitters. hydraulic balancing sufficient, change pump limitation settings ([9-0D] and [9-0E] if applicable). EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 59
If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
If you want to relocate parts of your system, contact your installer. You can find the contact/helpdesk number via the user interface. 1 Go to [8.3]: Information > Dealer information. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
WD curve type [5.E] (read only) 12.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] Information Dealer information [8.3] EBLA09~16DA + EDLA09~16DA User reference guide Daikin Altherma 3 M 4P620245-1A – 2021.02...
Page 68
4P620245-1A 2021.02 Verantwortung für Energie und Umwelt...