START CONDENS 25 - 29 Kis
9 After performing the necessary maintenance operations, the
original adjustments must be restored and the combustion prod-
uct analysis must be performed to check the correct operation.
9 Do not clean the appliance or any latter part with flammable sub-
stances (e.g. petrol, alcohol, etc.).
9 Do not clean panelling, enamelled and plastic parts with paint
solvents.
9 Panels must be cleaned with ordinary soap and water only.
Burner cleaning
The flame side of the burner is made with an innovative material
of the latest generation.
• Be especially careful during the dismantling, handling and installa-
tion of the burner and the components next to it (e.g.. electrodes,
insulation panels, etc.).
• Avoid direct contact with any cleaning device (e.g. brushes, va-
cuum cleaners, blowers, etc.).
In general, the burner does not require maintenance, but particu-
lar cases may occur where cleaning is necessary (e.g.. distribution
network of gas containing solid particles and in the absence of a
filter on the line, suction air containing excessively adhesive parti-
culates, etc.).
For this reason, perform a visual control of the burner in order to
ensure the proper functioning of the product:
• remove the front cover of the air box
• unscrew the fastening nut of the gas train to the valve, remove the
gas train spring clip to the mixer and turn the gas train outwards
• remove the silencer from the mixer
• disconnect the connectors of the wiring from the fan and the con-
necting cables of the electrodes
• unscrew the fixing screws and remove the exchanger-fan cover
assembly from its seat
• unscrew the fixing screws and remove the burner from its seat
checking it condition
9 If necessary, clean the burner with compressed air, blowing
from the metal side of the burner.

9 - Technical data

Description
Fuel
Appliance category
Country of destination
Type of appliance
Heating
Nominal heat input
Nominal heat output (80/60°C)
Nominal heat output (50/30°C)
Reduced heat delivery
Reduced heat output (80/60°C)
Reduced heat output (50/30°C)
Nominal Range Rated thermal output (Qn)
Minimum Range Rated thermal output (Qn)
Domestic hot water
Nominal heat input
Nominal heat output (*)
Reduced heat delivery
Reduced heat output (*)
Efficiency
Useful efficiency Pn max - Pn min (80/60°C)
Useful efficiency 30% (47° C return)
Useful efficiency Pn max - Pn min (50/30°C)
Useful efficiency 30% (30° C return)
Efficiency at average Pn Range Rated (80/60°C)
Combustion efficiency
Residual discharge head of boiler without pipes
Flow rate CH
9 It is possible that with ageing, the fibres constituting the
flame side of the burner can tone the colour.
• Reassemble everything in reverse order.
9 If necessary, proceed with the replacement of the sealing
gaskets.
The manufacturer declines all responsibility for any damage caused
from the failure to observe that stated above.
8.1 - Boiler cleaning
Before any cleaning operation, switch off the electrical supply by
turning the system's main switch to "Off".
External cleaning
Clean the housing, the control panel, the painted parts and the plas-
tic parts with a cloths dipped in soap and water.
In the case of stubborn stains dampen the cloth with a mixture of
50% water and methylated spirit or with specific products.
0 Do not use fuels and/or sponges soaked in abrasive solutions or
powder detergents.
Internal cleaning
Before starting internal cleaning operations:
• Close the gas shut-off valve
• Close the system taps.
Start Condens 25 Kis
G20
B23P, B53P, C13-C13x, C33-C33x, C43-C43x, C53-C53x,
kW
20,00
kW
19,50
kW
20,84
kW
5,00
kW
4,91
kW
5,36
kW
20,00
kW
15,30
kW
25,00
kW
25,00
kW
5,00
kW
5,00
%
97,5 - 98,1
%
102,2
%
104,2 - 107,2
%
108,6
%
97,4
%
97,9
Pa
100
32
Start Condens 29 Kis
G31
G20
II2H3P
(+)
C83-C83x, C93-C93x
25,00
24,45
26,23
6,00
5,90
6,40
25,00
17,00
29,00
29,00
6,00
6,00
97,8 - 98,3
102,0
104,9 - 106,7
108,6
97,3
98,1
110
G31