Emerson wirelessHART Rosemount Series Quick Start Manual page 22

Table of Contents

Advertisement

Quick Start Guide
Heavy-duty cable BFOU(c). Different cable models may vary its wires colors.
Contact your Emerson representative for assistance when using different
cable models.
Table 4-1: Wiring scheme - single element ER probe
Junction box
(Terminal :: Pin)
J1 :: 1
J1 :: 2
J2 :: 1
J2 :: 2
J3 :: 1
J3 :: 2
Table 4-2: Wiring scheme - LPR probe
Junction box
(Terminal :: Pin)
J3 :: 3
J3 :: 4
J3 :: 5
J3 :: 6
Not connected
Not connected
Table 4-3: Wiring scheme - Galvanic probe
Junction box
(Terminal :: Pin)
J2 :: 4
J2 :: 5
Not connected
Not connected
Not connected
Not connected
22
Signal name
IE+ / ERE1+
IE- / ERE1-
RefA / ERR1+
RefB / ERR1-
E1A / ERM1+
E1B / ERM1-
Signal name
Counter / LPR-C
Ref / LPR-R
Working-I / LPR-WI
Working-V / LPR-
WV
None
None
Signal name
GALV+
GALV-
None
None
None
None
Standard cable
Multicable
Pink
Brown
Grey
Green
White
Yellow
Standard cable
Multicable
Pink
White
Yellow
Brown
Grey
Green
Standard cable
Multicable
Yellow
White
Pink
Brown
Grey
Green
Emerson.com/Rosemount
April 2021
Heavy-duty cable
BFOU(c)
Black1
Brown2
Black2
Blue2
Blue1
Brown1
Heavy-duty cable
BFOU(c)
Black1
Blue1
Brown1
Brown2
Black2
Blue2
Heavy-duty cable
BFOU(c)
Brown1
Blue1
Black1
Brown2
Black2
Blue2

Advertisement

Table of Contents
loading

Table of Contents