Table 3-3: Supported probe types (continued)
Transmitter model
4392 Erosion Wireless Transmitter
2. Set the Acquisition Rate. The acquisition rate is the time interval
between each sensor data point measurement and can be selected
from 1 minute up to 24 hours.
3. Add the Input Parameters for the probe you are using. The probe
parameters depend on the probe type:
Figure 3-5: Configure sensor tab – AMS Device Manager
Quick Start Guide
For ER probes, the parameters are Element Thickness and Metal
Loss Offset
For LPR probes, the parameters are Working Electrode Area,
Rate Factor, and B Constant.
Galvanic probes do not require input
A. Probe type selection list
B. Acquisition rate configuration field
C. Input parameters configuration field
Supported probe types
Multiple element ER sand
erosion probe
Multiple element ER combined
probe