Self-Diagnostic Error Codes - NAiS FP Series Hardware Manual

Programmable controller
Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

Self-Diagnostic and Troubleshooting
Error
Name of error
code
E8
Operand error
(OPR COMBI)
11.3.3

Self-Diagnostic Error Codes

Error
Name of error
code
E31
Interrupt error 1
E32
Interrupt error 2
E45
Operation error
E100
Self-diagnostic
to
error set by
E199
F148 (ERR)
F148 (ERR)
instruction
E200
to
E299
11-12
Operation
Description and steps to take
status
Stops
There is an incorrect operand in an instruction which requires a
specific combination operands (for example, the operands must all be
of a certain type).
Enter the correct combination of operands.
Operation
Description and steps to take
status
Stops
An interrupt occurred without an interrupt request.
A hardware problem or error due to noise is possible.
Turn OFF the power and check the noise conditions.
Stops
An interrupt occurred without an interrupt request.
A hardware problem or error due to noise is possible.
Turn OFF the power and check the noise conditions.
There is no interrupt program for an interrupt which occurred.
Check the number of the interrupt program and change it to agree
with the interrupt request.
Selects
Operation became impossible during a high-level instruction. The
cause of the operation error varies depending on the instruction. In
system register 26, select "1: Continue operation" or "0: Stop"
Stops
The error set using high-level instruction F148(ERR) has occurred.
Clear the error based on the set detection conditions