FP0 Hardware
Note
The output number given above is the output number when the
expansion output unit is installed as the first expansion unit
(see page 7 -
When the load voltage differs from the 24V DC external power supply for driving
the internal circuit
Other than 24V DC load voltage, 5V DC and 12V DC and other load voltages can be
connected.
FP0-E8YT/E16YT
Internal circuit
Internal circuit
Internal circuit
Matsushita Electric Works (Europe) AG
4).
Output side
(+)
Y20
Load (for 5V )
Y21
Load (for 5V )
Y2n
Load (for 24V DC)
(–)
3.3
Internal Circuit Diagram
5V DC
24V DC
(Rated load
(External
voltage)
power supply
for driving
internal circuit)