NAiS FP Series Hardware Manual page 48

Programmable controller
Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

FP0 Hardware
FP0–E16T/E16P/E8X
Number of
8
input points
per common
5
which are
4
simultaneously
ON
Ambient temperature (5C/5F)
FP0–E32T/E32P/E16X
16
Number of
input points
per common
9
which are
8
simultaneously
ON
Ambient temperature (5C/5F)
3.2.3
Output Specifications
Relay Output Type
FP0 relay output types: E8RS and E16RS
Item
Output type
Rated control capacity
Output points per
E8RS
common
E16RS
OFF ↔ ON
Response time
ON ↔ OFF
Mechanical life time
Electrical life time
Matsushita Electric Works (Europe) AG
at 26.4V DC
at 24V DC
34/
43/
55/
93.2
109.4
131
at 26.4V DC
at 24V DC
26/
34/
55/
78.8
93.2
131
Description
Normally open (1 Form A) relay output
2A 250V AC, 2A 30V DC (4.5A maximum per common)
4 points/common
8 points/common
approx. 10ms
approx. 8ms
20,000,000 operations or more
100,000 operations or more
3.2
Specifications
3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0