NAiS FP Series Hardware Manual page 164

Programmable controller
Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

FP0 Hardware
Address
Name of system register
Input
400
High-speed
setting
counter mode
settings (X0 to
x2)
Notes
If the operation mode is set to 2–phase, individual, or direction
differentiation, the setting for CH1 is invalid.
If reset input settings overlap, the setting of CH1 takes
precedence.
If system register 400 to 403 have been set simultaneously for
the same input relay, the following precedence order is
effective: [High–speed counter] –> [Pulse catch] –> [Interrupt
input].
Matsushita Electric Works (Europe) AG
Default
value
Setting by FP
H0
programmer II
A.2
Tables of System Registers
Set value (parameter)
CH0/
H 0
0
CH1
0: Do not use high-
speed counter.
1: 2-phase input (X0,
X1)
2: 2-phase input (X0,
X1), Reset input
(X2)
3: Incremental input
(X0)
4: Incremental input
(X0), Reset input
(X2)
5: Decremental input
(X0)
6: Decremental input
(X0), Reset input
(X2)
7: Individual input (X0,
X1)
8: Individual input (X0,
X1), Reset input
(X2)
9: Direction dicision
(X0, X1)
A: Direction dicision
(X0, X1), Reset
input (X2)
0: Do not use high-
speed counter.
3: Incremental input
(X1)
4: Incremental input
(X1), Reset input
(X2)
5: Decremental input
(X1)
6: Decremental input
(X1), Reset input
(X2)
A-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp0

Table of Contents