Special Data Registers
Notes
1) Scan time display is only possible in RUN mode, and shows
the operation cycle time. The maximum and minimum values
are cleared when each the mode is switched between RUN
mode and PROG. mode.
2) Used by the system.
Addresses
T32CP
Other Types
DT90038
DT9038
DT90039 to
DT9039 to
DT90043
DT9043
DT90044
DT9044
DT90045
DT9045
DT90046
DT9046
DT90047
DT9047
DT90048
DT9048
DT90049
DT9049
DT90050
DT9050
DT90051
DT9051
C-4
Description
Work 2 for F96 (SRC) instruction
The position of the first matching data, counting from the starting 16-bit area, is
stored here when an F96 (SRC) instruction is executed.
Not used
High-speed counter elapsed value for ch0
The elapsed value (24–bit data) for the high–speed counter is stored here. Each time
the ED instruction is executed, the elapsed value for the high–speed counter is auto-
matically transferred to the special registers DT9044 and DT9045.
The value can be written by executing a DMV (F1) instruction.
High-speed counter target value for ch0
The target value (24–bit data) of the high–speed counter specified by the high–speed
counter instruction is stored here.
counter instruction is stored here.
Target values have been preset for the various instructions, to be used when the
high–speed counter related instruction F166 to F170 is executed. These preset val-
ues can only be read, and cannot be written.
High-speed counter elapsed value area for ch1
The elapsed value (24–bit data) for the high–speed counter is stored here. Each time
the ED instruction is executed, the elapsed value for the high–speed counter is auto-
matically transferred to the special registers DT9048 and DT9049.
The value can be written by executing a DMV (F1) instruction.
High-speed counter target value area for ch1
The target value (24–bit data) of the high–speed counter specified by the high–speed
counter instruction is stored here.
counter instruction is stored here.
Target values have been preset for the various instructions, to be used when the
high–speed counter related instruction F166 to F170 is executed. These preset val-
ues can only be read, and cannot be written.
Matsushita Electric Works (Europe) AG