IdentifyBridge
Enabling this option causes the front panel Ready LED of
the FastStream to blink until the parameter is disabled.
Default: disabled
set IdentifyBridge [enabled | disabled]
get IdentifyBridge
Info
Displays version numbers and other production
information for key components.
Info
IPAddress
Regulates the current FastStream IP address.If
IPDHCP
is enabled (see below), get command reports
the current IP address assigned by the network DHCP
server.
Default IP Address: 10.0.0.1
set IPAddress [mp1] xxx.xxx.xxx.xxx
Requires a SaveConfiguration Restart command
get IPAddress [mp1]
IPDHCP
Selecting DHCP allows the FastStream to request an IP
address from the network. The network must have at least
one DHCP server.
Default: enabled
set IPDHCP [mp1] [enabled | disabled]
Requires a SaveConfiguration Restart command
get IPDHCP [mp1]
IPGateway
Controls the current default gateways used by the
Ethernet port on the unit. If
command reports the current IP gateway assigned by the
network DHCP server.
Default: 0.0.0.0
set IPGateway [mp1] [xxx.xxx.xxx.xxx]
Requires a SaveConfiguration Restart command
get IPGateway [mp1]
IPSubnetMask
Sets/displays the current subnet mask. If
enabled, get command reports current subnet mask
assigned by DHCP server.
Default: 255.255.0.0
set IPSubnetMask xxx.xxx.xxx.xxx
Requires a SaveConfiguration Restart command
get IPSubnetMask
IPDHCP
is enabled, the get
IPDHCP
is
IsReserved
Displays the reservation status of the FastStream.
IsReserved
MaxOpTemp
Regulates the maximum operating temperature of this
unit in degrees Celsius. Valid entries are between 55 ° C
and 70 ° C.
Default: 70
set MaxOpTemp [55 – 70]
Requires a SaveConfiguration Restart command
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a
product via the command's Start, Stop and Display
parameters.
Metrics [Start | Stop | Display| Clear] [drive [BlockDevID]
| all | running]
MinOpTemp
Regulates the minimum operating temperature of this unit
in degrees Celsius. Valid entries are between 0 ° C and
15 ° C.
Default: 0
set MinOpTemp [0 – 15]
Requires a SaveConfiguration Restart command
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid
entries are between 0 ° C and 15 ° C.
Default: 0
set OpTempWarn [0 – 15]
Requires a SaveConfiguration Restart command
get OpTempWarn
PartitionDisplay
Lists all the partitions available in the specified RAID
group. The partitions are listed in order of
contiguousness (as opposed to index order).
PartitionDisplay [GroupName]