ATTO Technology FastStream VT 5300 Installation And Operation Manual page 46

Fibre channel to scsi virtual tape appliance
Hide thumbs Also See for FastStream VT 5300:
Table of Contents

Advertisement

DefaultInterleave
Assigns or retrieves the system-default interleave size for
new RAID groups. If an interleave size is not explicitly
specified when a RAID group is created, then the
DefaultInterleave value is used instead.
Default: 128
set DefaultInterleave [16 | 32 | 64 | 128 | 256 ]
get DefaultInterleave
DeleteAllMaps
Removes all mapped devices from the map table. Upon
the subsequent POST, the default maps are loaded if no
maps are present.
DeleteAllMaps
SaveConfiguration command required
DHCPFixedDelay
Selects/displays the delay, in seconds, between DHCP
client request intervals, from between 0 seconds to 255
seconds. 0 time is typical.
Default: 0 (no delay)
set DHCPFixedDelay [ 0 - 255 ]
Requires a SaveConfiguration command
get DHCPFixedDelay
DisplayEventLog
Displays the
EventLog
.The event log may be filtered
using the
DisplayEventLogFilter
optional parameter n is the number of lines to be
a single page with no user
displayed as
interaction. After the command has executed,
use
+, - or = to scroll through the log. Type quit and
press Enter to exit the command.
DisplayEventLog <n>
DisplayEventLogFilter
Filters the display of data for specified subsystems and
levels during
DisplayEventLog
subsystem entries are platform-dependent. For set
commands, the final parameter indicates whether or not
events from the specified subsystem and level is
displayed.
Default: all all all
set DisplayEventLogFilter [subsystem | all] [level | all] [all
| none]
Requires a SaveConfiguration command
get DisplayEventLogFilter [subsystem | all] [level | all]
xiii
ATTO Technology Inc. FastStream VT 5300 Installation and Operation Manual
command. The
mode. Valid event log
DriveTest
Starts or stops a drive test with a previously specified
configuration and drive list (refer to
and
DriveTestList
).Drives which are in-use by the test
are not available for RAID configuration or RAID
operations. Only one test can be run at a time. Drives to
be tested cannot be part of a RAID group or in use as Hot
Spares.
DriveTest [Begin | Cancel]
DriveTestConfig
Configures the next drive test to perform one of the
following operations: initialize (destructive write-only),
read (non-destructive read-only), verify (destructive
verify), or init-verify (destructive write-read-verify).The
test is not started until the
is given. Drives to be tested cannot be part of a RAID
group or in use as Hot Spares.
Default: not initiated
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test of drives
which are not part of a RAID group or which are Hot
Spares. The all parameter automatically chooses eligible
drives. The test is not started until the
command is given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test but
does not display performance metrics. If a block device
ID is not running or cannot be found, its state is idle and
percent complete is 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Displays the unit's configuration to a current CLI
session.
DumpConfiguration
DumpEventLog
Displays the contents of the entire event log to the current
CLI session without impact on the log itself (the log is not
cleared). No events are recorded until the command has
been completed.
DumpEventLog
DriveTestConfig
DriveTest
Begin command
DriveTest
Begin

Advertisement

Table of Contents
loading

Table of Contents