ATTO Technology FastStream VT 5300 Installation And Operation Manual page 50

Fibre channel to scsi virtual tape appliance
Hide thumbs Also See for FastStream VT 5300:
Table of Contents

Advertisement

Password
Specifies password for all non-serial sessions: Telnet, ftp
and FastStream browser-based user interface. You are
prompted for the current password, to type the new
password, and to confirm the new password. If local
echo is enabled, password echoes all * characters. In
verbose mode only, CLI requests the password be re-
typed. When the password is all 0s, Telnet and ftp do not
validate the password and MD5 authentication is
disabled. Passwords are case sensitive and can be 1-32
characters long with no spaces.
Default: Password
set Password
Requires a SaveConfiguration command
Performance
Returns the performance data for the FC port you specify.
Data includes the average rate (MB per sec.) and number
of I/Os measured over the previous sampling period
where a sampling period is approximately one second.
Successful SCSI Read (08h, 28h) and Write (Oah, 2Ah)
commands are considered I/Os.Reported performance
may be affected by FC port and SCSI bus availability and
saturation, SCSI device speeds and overall system use.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDCommandTimeout
Specifies in milliseconds the range of time the drives have
to respond. You must use RGCommit before using this
command.
CAUTION
CAUTION
If you set this value too low, failures may
occur during normal operation.
Default: 30000
set RAIDCommandTimeout [100 - 3600000]
Requires a SaveConfiguration Restart command
get RAIDCommandTimeout
xvii
ATTO Technology Inc. FastStream VT 5300 Installation and Operation Manual
RAIDRebuildPriority
Sets or displays the RAID rebuild priority. A RAID
rebuild priority set to high gives higher priority to RAID
rebuilds and lower priority to the processing of
simultaneous I/O transactions. A RAID rebuild priority
set to low gives lower priority to the rebuild and a higher
priority to I/O transactions. Set same, the RAID rebuild
and processing of I/O transactions is the same.
Default: same
set RAIDRebuildPriority [high | low | same]
Requires a SaveConfiguration command
get RAIDRebuildPriority
Reserve
Reports the state of CLI reservation for the current CLI
session. If the command reports that Reservations are
enabled, then another CLI session has control of
parameter modification on the unit.
Reserve
ResetFCPortErrors
ResetFCPortErrors resets all Fibre Channel error counts
for the specified port to zero. Refer to
ResetFCPortErrors [fp] [all]
RestoreConfiguration
Issued with the default option, forces the unit NVRAM
settings to their original defaults. The saved option
undoes any changes made to this session since the last
save.
RestoreConfiguration < Default | Saved >
RGAddStorage
Adds additional storage to an existing RAID group.
Mirror|Stripe|Span specifies the method used to
expand the storage. Optional parameter BlockDevID
specifies available block device(s) to be added to the
RAID group. Optional parameter commit specifies that
the
RGCommit
command is run automatically.
Note
Mirrors cannot be added to a RAID 5 group.
RGAddStorage [GroupName] [Mirror | Stripe | Span]
<BlockDevID> <commit>
RGCancelAddStorage
Cancels the
RGAddStorage
RGCancelAddStorage [GroupName]
FCPortErrors
.
command.

Advertisement