Fifo Interrupt Control - Base+06H (Pcm-3718Ho Only); A/D Status Register - Base+8 - Advantech PCM-3718 Series User Manual

Pc/104 12-bit das module with programmable gain
Table of Contents

Advertisement

4.7 FIFO Interrupt Control — BASE+06H (PCM-3718HO
only)
Table 4.3: Register for FIFO Interrupt Control
Write
Bit#
BASE+06H
FINT Enables/disables FIFO interrupt
0
1

4.8 A/D Status Register - BASE+8

Read-only register BASE+8 provides information on the A/D configura-
tion and operation. Writing to this I/O port with any data value clears its
INT bit. The other data bits do not change.
BASE+8 - A/D status
Bit
Value EOC
EOC
MUX
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
FIFO interrupt control
7
6
5
X
X
X
FIFO interrupt disabled
FIFO interrupt enabled
D7
D6
D5
N/A
MUX
End of Conversion.
0
The A/D converter is idle, ready for the next conversion.
Data from the previous conversion is available in the A/
D data registers.
1
The A/D converter is busy, implying that the A/D con-
version is in progress.
Single-ended/differential channel indicator.
0
8 differential channels
1
16 single-ended channels
4
3
2
X
X
X
D4
D3
D2
INT
CN3
CN2
37
1
0
X
FINT
D1
D0
CN1
CN0
Chapter 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm-3718hPcm-3718hgPcm-3718ho

Table of Contents