Advantech PCM-3718 Series User Manual page 63

Pc/104 12-bit das module with programmable gain
Table of Contents

Advertisement

RW1 & RW0
Operation
Counter latch
Read/write LSB
Read/write MSB
Read/write LSB first, then MSB
M2, M1 & M0
M2
0
0
X
X
1
1
BCD
BCD
0
1
If you set the module for binary counting, the count can be any number
from 0 up to 65535. If you set it for BCD (Binary Coded Decimal) count-
ing, the count can be any number from 0 to 9999.
If you set both SC1 and SC0 bits to 1, the counter control register is in
read-back command mode. The control register data format becomes:
BASE+15 - 8254 control, read-back mode
Bit
Value 1
PCM-3718 Series User Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Select read/write operation
Select operating mode
M1
M0
0
0
0
1
1
0
1
1
0
0
0
1
Select binary or BCD counting
Type
Binary counting 16-bits
Binary coded decimal (BCD) counting
D7
D6
D5
1
CNT
RW1
0
0
1
1
Mode
Description
0
Programmable one shot
1
Programmable one shot
2
Rate generator
3
Square wave rate generator
4
Software triggered strobe
5
Hardware triggered strobe
D4
D3
STA
C2
54
RW0
0
1
0
1
D2
D1
D0
C1
C0
X