4.1 A/D Data Registers - BASE+0/1

Two read-only registers at BASE+0 and BASE+1 hold A/D conversion
data. The 12 bits of data from the A/D conversion are stored in BASE+1
bit 7 to bit 0 and BASE+0 bit 7 to bit 4. BASE+0 bits 3 to 0 store the
source A/D channel number.
BASE+0 (read only) - A/D low byte & channel number
Bit
Value AD3
BASE+1 (read only) - A/D high byte
Bit
Value AD11
AD11 to AD0
C3 to C0

4.2 Software A/D Trigger - BASE+0

You can trigger an A/D conversion from software, the module's onboard
pacer or from an external pulse. Bits 1 and 0 of register BASE+9 (shown
on pages 31~32) select the trigger source. If you select software
triggering, a write to the register BASE+0 with any value will trigger an
A/D conversion.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
D7
D6
D5
AD2
AD1
D7
D6
D5
AD10
AD9
Analog to digital data. AD0 is the least significant bit
(LSB) of the A/D data, and AD11 is the most
significant bit (MSB)
A/D channel number from which the data is derived.
C3 is the MSB and C0 is the LSB
D4
D3
D2
AD0
C3
C2
D4
D3
D2
AD8
AD7
AD6
31
D1
D0
C1
C0
D1
D0
AD5
AD4