Introduction
The PCM-3614 is a PC/104-compatible module with four in-
dividually configurable RS-422/485 ports. It works with PC/
104 CPU modules to extend additional RS-422/485 ports. The
PCM-3614 also features lots of functions such as high trans-
mission speed 921.6 kbps, independent/shared IRQ and more.
It also provides high-performance 16C550 UART communi-
cation chip with 16-byte FIFO to reduce CPU load. This makes
the PCM-3614 especially suitable for multitasking environ-
ments.
The PCM-3614 comes with a Windows 95/98/NT/ME con-
figuration utility (Windows 2000/XP utility will soon be ready
and allowed to download through our Web site). The Win-
dows configuration utility provides functions such as self-di-
agnostics and performance analysis for easy troubleshooting
and debugging.
The PCM-3614 provides versatile function settings to meet
users' needs. These function settings include Standard/En-
hance mode, Independent/Shared IRQ mode and Speed
mode. Standard/Enhance mode setting helps the user use
base address more flexible. Especially in Enhance mode, dif-
ferent base addresses can be set according to the applica-
tion. In Shared IRQ mode, all ports of interrupt can be speci-
fied to one. This solves the problem of IRQ insufficiency within
the embedded system. In Speed mode, the PCM-3614 al-
lows transmission rate up to 921.6 kbps, improving the over-
all performance of the system.
Features
Four Independent RS-422/485 serial ports
Automatic RS-485 data flow control
Transmission speeds up to 921.6 Kbps
Shared IRQ settings for each port
Windows configuration utility for Windows 95/98/NT/ME
P.S. Windows 2000/XP/CE driver will soon be available on
our Web site
Built-in termination resistors
LED indicators: TX, RX
Standard PC ports: COM1, COM2, COM3, COM4
compatible
Specification
Bus interface: PC/104 (ISA)
Number of ports: 4
I/O address: 0x000 ~ 0x3F8
UART: 4 x 16C550
PCM-3614 User's Manual
PC/104 and the PC/104 logo are trademarks of the PC/104 Consortium
IRQ: 3, 4, 5, 6, 7, 9, 10, 11, 12, 15
Data bits: 5, 6, 7, 8
Stop bits: 1, 1.5, 2
Parity: none, even, odd
Speed (bps): 50 ~ 921.6K
Connectors: Four DB-9 male
Signal support: TxD+, TxD-, RxD-, CTS+, CTS-,
RTS+ and RTS-
Surge protection: 1000 V
DC
Temperature:Operating : 0 ~ 65° C
(refer to IEC-68-1-1,2) ( 32~149° F)
Storage : -25 ~ 80° C (-13~176° F)
Operation Humidity: 0% ~ 90% Relative
Humidity, non-condensing
Product Package
PCM-3614 PC/104 4-port RS-422/485 High-
Speed Module
Advantech ICOM Driver/Utility CD
One cable
Initial inspection
We carefully inspected the PCM-3614 both mechani-
cally and electrically before we shipped it. It should
be free of marks and scratches and in perfect elec-
trical order on receipt.
Handle the board only by its edges. The static change
on your body may damage its integrated circuits.
Keep the card in its anti-static package whenever it
is not installed. You can use this package to return
the card if it should need repair.
Board Layout
Part no. 2000364100 1st Edition
1
Printed in Taiwan August 2000

Advertisement

loading

Summary of Contents for Advantech PCM-3614

  • Page 1 RS-422/485 ports. It works with PC/ 104 CPU modules to extend additional RS-422/485 ports. The • Parity: none, even, odd PCM-3614 also features lots of functions such as high trans- • mission speed 921.6 kbps, independent/shared IRQ and more. Speed (bps): 50 ~ 921.6K It also provides high-performance 16C550 UART communi- •...
  • Page 2: Card Configuration

    To set the base address, you have to calculate the base Standard/Enhanced Mode (M0) address as follows: (switch ON is “0”, switch OFF is “1”.) PCM-3614 can be used in standard or enhanced mode. In Base address Decimal standard mode the I/O addresses are compatible with the...
  • Page 3 Shared IRQ (JP3) 090H 0A0H Select an IRQ which is not in use by another card in the sys- tem. If you are installing more than one PCM-3614, set them 0B0H to different IRQ numbers. Jumper Bank JP3 controls the card 0C0H IRQ.
  • Page 4 380H installed cards by reading a data file, GEN-DRV.CNF. When 390H you first install the PCM-3614, and each time you change the 3A0H card’s address and IRQ, you will need to run the card setup program to save the settings to the configuration file. Pro- 3B0H gram files should be installed to the hard disk.
  • Page 5: Quick Reference

    Port 4 2E8h COM4 PCM-3614 series cards can be installed together in a single system as long as the system memory resources are suffi- cient and available in a system. Different boards should be ENHANCED Mode: assigned different IRQs.
  • Page 6 CPU card. Do not tighten too Connect the right two pins of JP8 to use Windows 95/98/NT much, or the threads may be damaged. 6.Carefully align the pins of the PCM-3614 with the PC/104 Signal Wiring connector. Slide the module into the connector. The module pins may not slide all the way into the connector;...