Man Down
The timers are restarted anytime when the radio is moved before the Man-Down mode is
entered or when the PTT button is pressed.
The No-Movement Feature functionality may be used together with the Angle Feature
functionality but not the Movement Feature functionality. Both the No-Movement Feature and
Angle Feature functionalities may be possibly active at the same time and trigger independent
pre-alert tone.
17.4
Time to Pre-alert for Angle
This parameter sets the duration before playing an alert tone when used in the Angle Feature
functionality.
Type the required value in the field.
17.5
Time to Pre-alert for No-movement
This parameter sets the duration before playing an alert tone when used in the No-movement
Feature functionality.
Type the required value in the field.
17.6
Time to Alert for Angle
This parameter sets the duration the terminal waits to enter into Man Down mode after the pre-alert
sounded when used in the Angle Feature functionality.
Type the required value in the field.
17.7
Time to Alert for No-movement
This parameter sets the duration the terminal waits to enter into Man Down mode after the pre-alert
sounded when used in the Angle Feature functionality.
Type the required value in the field.
17.8
Activation Angle
This parameter defines the angle at which to trigger the Man Down timers to countdown to enter the
Man Down mode.
To change the value, choose from a drop down list.
17.9
No-movement Sensitivity
This parameter sets the sensitivity of the movement sensor which is used for either the
No-Movement or Movement Feature functionalities.
The sensitivity levels are:
Min - Minimum vibration/movement will activate the functionality
Med - Medium vibration will activate the functionality
Max - Maximum vibration will activate the functionality
To change the value, choose from a drop down list.
17.10 Pre-alert Repeat Enable
If enabled, the pre-alert tone is repeated once per Pre-alert Period.