To operate your GRPro 2.1 System, you need:
Control Unit filled with ice and water as indicated by the fill line labels within the
reservoir. Optimal performance is achieved by first adding 1.5 liters of water, and then
filling the reservoir to the top with ice.
Game Ready supplied power supply.
Connector Hose.
Wrap (includes a Heat Exchanger and Sleeve).
Notes:
The Wrap is comprised of an inner Heat Exchanger and an outer Sleeve. The combination
of Sleeve and Heat Exchanger is referred to throughout this manual as a "Wrap. " To ensure
proper performance, be sure to use ATX Series Heat Exchangers.
The Control Unit should be placed on a stable surface (such as the floor or a table) during
use.
Note that using the system in an environment with a high ambient temperature may
affect its ability to provide adequate cooling, or may limit the ice life.
If you will be using the system with a Game Ready optional battery pack (sold separately),
please consult the instructions for use that accompany that battery pack.
Priming the Wrap:
To prevent 04 errors at the beginning of therapy, it is important to prime the Wrap before a
therapy.
With the GRPro 2.1 Control Unit off, attach the Connector Hose to the Control Unit
and the Wrap
Lay the Wrap open and flat next to the Control Unit (not on the body)
Turn the System on and run for 2 minutes with No Pressure
The wrap is now ready for use and therapy may begin as instructed
Wrap priming instructions may vary depending on Wrap. Refer to the Wrap Use Guide
included with each Wrap for specific priming instructions.
Warning:
Your GRPro 2.1 Control Unit should be plugged into a grounded electrical outlet
prior to operation when using the FSP Power Supply. When using the Mega MDM-
030-A120-5396 power supply, a grounded electrical outlet is not required.
Position the Control Unit to minimize the risk of tripping over the Control Unit, Connector
Hose, or power cord.
Precautions:
Failure to properly follow the instructions of this manual and those of your medical
provider may interfere with or prevent delivery of appropriate therapy.
To avoid risk of electrical shock unplug the Control Unit from the electrical outlet prior to
filling the Control Unit with ice and water.
Push the door release button to open the reservoir door.
1
EN- 8

OPERATING THE SYSTEM

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GRPro 2.1 CONTROL UNIT and is the answer not in the manual?

This manual is also suitable for:

550550-03550550-03-rn550550-53Grpro 2.1 control unit

Table of Contents

Save PDF